Inverter Specifications
| SKU | VIC-MultiPlus-II-24/3000/70-50-2x120V-UL |
|---|---|
| Operating type | Off-grid |
| Inverter function | Inverter/charger |
| Continuous AC output power (W) | 2400.0 |
| AC output rating conditions | Inverter mode supplies 120 V to both legs, not 240 V split phase. 120/240 V is passed through only from a suitable AC source. L1 transfer <18 ms; L2 about 40 ms. |
| Continuous apparent power (VA) | 3000.0 |
| AC output voltage (V) | 120 |
| AC output frequency (Hz) | 60 |
Show all specifications (45)Show fewer specifications
| AC phase configuration | Single-phase |
|---|---|
| Output waveform | Pure sine wave |
| Battery support | Required |
| Nominal battery voltage (V) | 24 |
| Min battery voltage (V) | 19.0 |
| Max battery voltage (V) | 33.0 |
| Outage backup capability | Yes |
| Backup/EPS output power (W) | 2400.0 |
| Backup output voltage (V) | 120 |
| Surge output power (W) | 5500.0 |
| Max AC battery charging current (A) | 70.0 |
| Generator input supported | Yes |
| AC input voltage (V) | 120, 120/240 |
| AC input frequency (Hz) | 45–65 |
| AC input phase configuration | Single-phase, Split-phase |
| Max AC input current (A) | 50.0 |
| AC pass-through current (A) | 50.0 |
| Peak efficiency (%) | 94.0 |
| Idle/no-load consumption (W) | 11.0 |
| Standby consumption (W) | 4.0 |
| Efficiency and consumption conditions | Standby consumption is Search mode. |
| Parallel operation supported | Yes |
| Max parallel units | 6 |
| Communication interfaces | VE.Bus |
| Monitoring app or portal | Victron VRM |
| Remote control functions | Remote monitoring, Remote settings, Remote on/off |
| Required monitoring accessories | Cerbo GX or another compatible GX device and internet connection |
| Monitoring subscription requirements | VRM portal is free of charge. |
| Length (mm) | 148.0 |
| Width (mm) | 275.0 |
| Height (mm) | 578.0 |
| Weight (kg) | 22.0 |
| Enclosure rating | IP22 |
| Min operating temperature (°C) | -40.0 |
| Max operating temperature (°C) | 65.0 |
| Temperature and altitude derating | 2200 W at 40°C; 1700 W at 65°C. |
| Cooling method | Fan-cooled |
Description
SKU: VIC-MultiPlus-II-24/3000/70-50-2x120V-UL
MFG SKU: PMP242305132
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid.
It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.