| Battery support | Optional |
| Supported battery chemistries | LiFePO₄
|
| Compatible batteries and BMS | Use the battery and SYN transfer equipment specified for the inverter hardware revision.
|
| Outage backup capability | Yes |
| Required backup accessories | Compatible battery system, Revision-matched Growatt SYN transfer equipment
|
| Solar PV input supported | Yes |
| Max recommended PV array power (W) | 17100.0 |
| Max DC input voltage (V) | 600.0 |
| PV startup voltage (V) | 50.0 |
| Min MPPT voltage (V) | 50.0 |
| Max MPPT voltage (V) | 550.0 |
| Independent MPPT count | 4 |
| PV strings per tracker | 2 |
| Max PV operating current (A) | 13.5 |
| PV operating-current limit basis | Per tracker |
| Max PV short-circuit current (A) | 16.9 |
| PV short-circuit current limit basis | Per tracker |
| PV input and tracker conditions | Ratings from the model-specific technical data. Confirm V2/V3 hardware before selecting battery and transfer accessories. |
| Peak efficiency (%) | 98.5 |
| Weighted efficiency (%) | 98.0 |
| Weighted efficiency standard | CEC |
| Standard warranty (years) | 10.0 |
| Warranty extension options | Manufacturer lists optional 15- and 20-year warranty extensions. |
| Display | LED indicators |
| Communication interfaces | RS485
|
| Wi-Fi availability | Optional accessory |
| Monitoring app or portal | Growatt monitoring platform |
| Length (mm) | 187.0 |
| Width (mm) | 400.0 |
| Height (mm) | 638.0 |
| Weight (kg) | 20.5 |
| Installation environment | Indoor/outdoor |
| Enclosure rating | NEMA 4X / IP65 |
| Min operating temperature (°C) | -25.0 |
| Max operating temperature (°C) | 60.0 |
| Temperature and altitude derating | Output derates above 45°C. |
| Max operating altitude (m) | 3000.0 |
| Cooling method | Passive |
| Certifications | UL 1741, UL 1741 SA, CSA C22.2, UL 1998, UL 1699B
|
| Grid standards and listings | IEEE 1547, CA Rule 21, HECO Rule 14
|
| Applicable regions and model variants | North America
|
| MPN | MIN 11400TL-XH-US |
|---|